  diesel engine-generator set 125-JC6DT3 125 ekw / 60 hz / standby 115 ekw / 60 hz / prime 208 - 600v a tognum g roup brand sy ste m r atings standby voltage (l-l) 240v** 240v** 208v** 240v** 480v** 600v** phase 1 1 3 3 3 3 pf 1.0 1.0 0.8 0.8 0.8 0.8 hz 60 60 60 60 60 60 kw 125 125 125 125 125 125 kva 125 125 156.25 156.25 156.25 156.25 amps 521 521 434 376 188 150 skva@30% voltage dip 136 195 250 250 330 334 generator model* 431psl6204 431psl6224 363csl1607 363csl1607 363csl1607 363psl1658 temp rise 130c/27c 130c/27c 130c/27c 130c/27c 130c/27c 125c/40c connection 12 lead zig-zag 4 lead 12 lead low wye 12 lead hi delta 12 lead hi wye 4 lead wye prime voltage (l-l) 240v 240v 208v 240v 480v 600v phase 1 1 3 3 3 3 pf 1.0 1.0 0.8 0.8 0.8 0.8 hz 60 60 60 60 60 60 kw 115 115 115 115 115 115 kva 115 115 138 143.75 143.75 143.75 amps 479 479 399 346 173 138 skva@30% voltage dip 136 195 250 250 330 335 generator model* 431psl6204 431psl6224 363psl1607 363psl1607 363psl1607 363psl1658 temp rise 105c/40c 105c/40c 105c/40c 105c/40c 105c/40c 105c/40c connection 12 lead zig-zag 4 lead 12 lead low wye 12 lead hi delta 12 lead hi wye 4 lead wye * the generator model number identifed in the table is for standard c series confguration. consult the factory for alternate confguration. ** ul2200 ofered
2 /// / 125-jc6 dt 3 // engine air cleaners oil pump full flow oil filter jacket water pump thermostat exhaust manifold C dry blower fan & fan drive radiator - unit mounted electric starting motor - 12v governor C electric isochronous base - formed steel sae flywheel & bell housing charging alternator - 12v battery box & cables flexible fuel connectors flexible exhaust connection epa certifed engine // g enerator nema mg1, ieee and ansi standards compliance for temperature rise and motor starting sustained short circuit current of up to 300% of the rated current for up to 10 seconds self-ventilated and drip-proof superior voltage waveform digital, solid state, volts-per-hertz regulator no load to full load regulation brushless alternator with brushless pilot exciter 4 pole, rotating field 130c standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 1% voltage regulation 100% of rated load - one step 3% maximum harmonic content // d igital control panel(s) digital metering engine parameters generator protection functions engine protection sae j1939 engine ecu communications windows-based software multilingual capability remote communications to our rdp-110 remote annunciator 16 programmable contact inputs 7 contact outputs ul recognized, , ce approved event recording ip 54 front panel rating with integrated gasket nfpa110 level compatible standard equip ment // epa tier 3 certifed // engine-generator set tested to iso 8528-5 for transient response // ul2200, csa listing ofered // accepts rated load in one step per nfpa 110, level 1 // all engine-generator sets are prototype and factory tested // mtu onsite energy is a single source supplier // global product support // 2 year standard warranty // custom design for any application // 6068hf285 diesel engine - 6.8 liter displacement - 4-cycle // complete range of accessories // permanent magnet generator (pmg) - optional - brushless, rotating field - 300% short circuit capability - 2/3 pitch windings // digital control panel(s) - ul recognized, , nfpa 110 - complete system metering - lcd display // cooling system - integral set-mounted - engine driven fan f acts
3 /// / 125-jc6 dt 3 // engine manufacturer john deere model 6068hf285 type 4-cycle arrangement 6 in-line displacement: cu in (lit) 415 (6.8) bore: in (cm) 4.19 (10.6) stroke: in (cm) 5 (12.7) compression ratio 19:1 rated rpm 1,800 engine governor jdec max power: standby: bhp (kwm) 237 (177) max power: prime: bhp (kwm) 216 (161) regulation .25% frequency 60 hz air cleaner dry // liquid capacity (lubrication) total oil system: gal (lit) 5.28 (20) engine jacket water capacity: gal (lit) 3.25 (12.3) system coolant capacity: gal (lit) 6 (22.7) // electrical electric volts dc 12 cold cranking amps under 0f (-17.8c) 800 // fuel system fuel supply connection size 3/8 npt fuel return connection size 3/8 npt maximum fuel lift: ft (m) 10 (3) recommended fuel diesel #2 total fuel flow: gal/hr (lit/hr) 28.3 (107.2) // fuel consumption standby prime at 100% of power rating: gal/hr (lit/hr) 8.9 (33.7) 8 (30.3) at 75% of power rating: gal/hr( lit/hr) 6.9 (26.1) 6.2 (23.5) at 50% of power rating: gal/hr (lit/hr) 5 (18.9) 4.5 (17) // cooling - r adiator system standby prime ambient capacity of radiator: f (c) 122 (50) 122 (50) maximum allowable static pressure on rad. exhaust: in. h 2 0 (kpa) 0.5 (0.12) 0.5 (0.12) water pump capacity: gpm (lit/min) 48 (180) 48 (180) heat rejection to coolant: btum (kw) 5,324 (93.5) 4,792 (84.3) heat rejection to air to air: btum (kw) 1,821 (32) 1,702 (30) heat radiated to ambient: btum (kw) 922 (16.2) 815 (14.3) // air r equirements standby prime aspirating: *scfm (m 3 /min) 480 (13.6) 452 (12.8) air flow required for rad. cooled unit: *scfm (m 3 /min) 17,712 (502) 17,712 (502) air flow required for heat exchanger/remote rad. based on 25f rise: *scfm (m 3 /min) 2,080 (59) 1,837 (52) * air density = 0.0739 lbm/ft 3 (1.184 kg/m 3 ) // exhaust system standby prime gas temp. (stack): f (c) 941 (505) 916 (491) gas volume at stack temp: cfm (m 3 /min) 1,201 (34) 1,165 (33) maximum allowable back pressure: in. h 2 0 (kpa) 30 (7.5) 30 (7.5) a pplication data
4 /// / 125-jc6 dt 3 ? mtu onsite energy. subject to alteration due to technological advances. 2009-05 // t ognum g roup companies: europe / m iddle east / africa / latin america / mtu onsite energy / 88040 friedrichshafen / germany / phone + 49 7541 90 7060 / fax +49 7541 90 7084 / powergenregion1@mtu-online.com // asia / australia / pacifc / mtu onsite energy / 1, benoi place / singapore 629923 / republic of singapore / phone + 65 6861 5922 / fax + 65 6861 3615 / powergenregion2@mtu-online.com // u sa / canada / m exico / mtu onsite energy / 100 power drive / mankato, minnesota 56001 / usa / phone + 1 507 625 7973 / fax + 1 507 625 2968 / powergenregion3@mtu-online.com // worldwide for hot module / mtu onsite energy / 81663 munich / germany / phone + 49 89 203042 800 / fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com emissions data no x + nmhc co pm 2.65 0.98 0.13 all units are in g/hp-hr and are epa d 2 cycle values. (plvvlrohhovrwhhjlhpddudvdfwlrrdpel - qpsuduedurpulsuuplgliosdqg tdollqdoodlrqsdudpupdulqjlqupqdlrq gddsurylggduoderudruuoiurprqqjlq usuqlqjludlqjgdddredlqgqgurq - uroogqylurqpqdorqgllrqldoleudglqupqdlrq uddeorqlg6d1dlrqdoudri6dqgdug dqglqrpsoldql63ujodlrqirqgllq5 3duljgoydoiurpdqjlqljdudq - greeor636dqgdugd63gqg rqgllrq 5 11216121216 // pelhwfdsdelolwdfwrudwwprvowru orfdo082vlwh(huj3rhu*hhudwlrlvwulewruru rwhudowlwghv // 6wdgeudwljvdssowrlvwdoodwlrvvhuhgeduholdeoh lolrudqgeudlqjldssoldeorydulqj ordgirugudlrqridsrurdj1rryuordgdsd - eloliruludlqj5dlqjdulqdrugdql 6266dqg1 // 3ulphsrhuudwljvdssowrlvwdoodwlrvhuhwlolwsrhu lvddlodeohruuholdeohwduljordgwhpehur jhhudwruvhwrshudwljruvlvolplwhgrhuordg fdsdflwlvddlodeohrurhrulwhoh5dwljvduhl dffrugdfhlw62rhuordgsrhuldffrugdfh lw6266dg1)ru olplwhguljwlphdgedvhordgudwljvfrvowwh idru // hudwlr)dfwru altitude shuwpderhwp dgshuwpderhwp t emperature shu)derh) : (*+610(16216 sound data u nit t ype standby full load standby n o load prime full load prime n o load opu w/critical grade mufer (dba) 91.5 84 90 84 sound attenuated enclosure (dba) 83.5 76 82 76 system dimensions (l x w x h) weight (less tank) opu 105 x 36 x 52 in (2,670 x 910 x 1,320 mm) 2,821 lb (1,280 kg) drawing above for illustration purposes only, based on standard open power 480 volt generator. lengths may vary with other voltages. do not use for installation design. materials and specifcations subject to change without notice. measurements for sound data are taken at 23 ft (7 m). weights and dimensions are based on open power units and are estimates only. consult the factory for accurate weights and dimensions for your specifc generator set.


▲Up To Search▲   

 
Price & Availability of 125-JC6DT3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X